THB | STANDARD MODULAR FRL (F/R+L) COMBO FRL89

THB | STANDARD MODULAR FRL (F/R+L) COMBO FRL89


Specifications
SKU
5
PORT SIZE
FRL 803 (MANUAL)(3/8"), FRL 804 (MANUAL)(1/2"), FRL 803A (AUTO)(3/8"), FRL 804A (AUTO)(1/2")
Details

F.R.L. AIR CONTROL UNIT 

Air Filter/Regulator/Lubricator Modular (Regular type
 

绌哄瑾跨悊绲 / 鍏╂寮忎笁榛炵祫鍚

Air Filter/Regulator/Lubricator Modular (F.R.L. air control unit) / Air C ombination / Air Source Treatment / Modular FRL Units / Air Preparation / Air Preparation Unit / Filter Regulator Lubricator Combinations / FRL Combination Units / Filter, Regulator, Lubricator Combinations / FRL Filtro regulador lubricador / Filtro FRL regulador lubrificador / Druckluft Aufbereitung / Filtro regolatore lubrificatore / 肖懈谢褜褌褉-胁谢邪谐芯芯褌写械谢懈褌械谢褜 / 袪械谐褍谢褟褌芯褉 写邪胁谢械薪懈褟 / 袥褍斜褉懈泻邪褌芯褉 / Filtre régulateur lubrificateur / filtre, regulatorer, smøreapparater / Filter, regulatorer, smörjare / 銉曘偅銉偪銉偖銉ャ儸銉笺偪+銉儢銉偙銉笺偪 / FRL銉︺儖銉冦儓 / 銉偢銉ャ儵銈裤偆銉桭.R.L.銈炽兂銉撱儘銉笺偡銉с兂 / SARTLANDIRICI / ثلاث نقاط الجمع / 绌烘埃瑾跨悊绲 / 涓夐粸閬庢烤鍣
 

SPECIFICATION:

 Part No.          C892 C893 C894 C832 C833 C834 FRL834H
 Description FRL892 FRL893 FRL894 FRL832 FRL833 FRL834
 Medium Air
 Port Size (PT, NPT) 1/4'' 3/8'' 1/2'' 1/4'' 3/8'' 1/2'' 1/2''
 Filter Element
 Proof Input Pressure  Psi 215 250 355
Mpa 1.5 1.7 2.4
 Proof Output   Pressure  Psi 145 215 284
Mpa 0.99 1.5 2
 Max Flow (L/min) 1750 2500 3000 1750 2500 3000 2500
 Operation Temperature   Range 5 ~  60
 Drain Capacity 80 ml
 Oil Capacity 150 ml
 Minimum Dripping Flow Rate   (L/min(ANR))* 1/4'': 30   3/8'': 40   1/2'': 50
 Recommendable Lubricants ISO VG-32
More Options
 Air Filter F892 F893 F894 F832 F833 F834  X
 Regulator R892 R893 R894 R832 R833 R834
 Air Filter + Regulator FR892 FR893 FR894 FR832 FR833 FR834
 Lubricator L892 L893 L894 L832 L833 L834

* The flow rate is 5 drops or greater/min under the following conditions : Inlet pressure of 0.5 MPa; Class 1 turbine oil (ISO VG32); Temperature at 20°C; Oil adjustment valve fully open.

* For a circuit that repeatedly turns ON and OFF on the outlet side, make the adjustment so that the average air consumption per minute becomes the minimum dripping flow rate or more.

* Lubrication cannot be properly performed if the operating flow rate is too low. Select an appropriately size lubricator by referring to the minimum dripping flow rate provided in the catalog. 

 

FEATURES:

1. Steel guards offer better protection.

2. Easy installation and disassembly.


View more about THB | STANDARD MODULAR FRL (F/R+L) COMBO FRL89 on main site